Hotline
+8618015094933
Pressure parameters | |||
range | -0.1MPa┅0MPa~0.01 MPa┅100MPa | ||
overload | 2 times the full range pressure or 110MPa (take the minimum) | ||
pressure type | Gauge pressure, absolute pressure, seal gauge pressure | ||
Electrical parameters | |||
type of output | current mode | voltage source | |
power supply | 9~30V DC | 12~30V DC | |
output signal | 4mA~20mA DC(Two wire system | 0/1V~5/10V DC (Three-wire) | |
load resistance | ≤(U-9)/0.02 | ≥10k | |
insulation resistance | 100MΩ,100V DC | ||
structure parameters | |||
housing | stainless steel | ||
sensor | 316Lstainless steel | ||
sealing ring | VITON | ||
cable | 7.5mm polyethylene special cable | ||
protection grade | IP65 (plug-in type) | IP68 (cable type) | |
environmental condition | |||
Media applicability | Various fluids that are non corrosive to 316L stainless steel and fluororubber | ||
compensation temperature | -10℃~+80℃ | ||
operation temperature | -30℃~+80℃ | ||
Storage temperature | -40℃~125℃ | ||
performance index | |||
accuracy | ± 0.25% FS (typical) | ± 0.5% FS (maximum) | |
zero temperature | 0.03%FS/℃(≤100kPa);0.02%FS/℃(>100kPa) | ||
Full temperature coefficient | 0.03%FS/℃(≤100kPa);0.02%FS/℃(>100kPa) | ||
Long term stability | ±0.3%FS/year(maximum) |